ما

modular hip bimod

Modular straight stem bipolar prostheses and accessories.

Download scientific diagram | Modular straight stem bipolar prostheses and accessories. from publication: Primary modular straight stem cemented prosthetic replacement for unstable, comminuted ...

ادامه مطلب

Effects of Cobalt and Chromium Levels Following Modular Hip

Due to the increased number of revision total hip arthroplasties (THAs) to correct pain secondary to fretting from modular hip stems, this study was conducted in an effort to correlate objective findings of serum cobalt (Co) levels, serum chromium (Cr) levels, and/or reactive tissue seen on metal artifact reduction sequence (MARS) magnetic …

ادامه مطلب

Novel concept of a modular hip implant could contribute …

ادامه مطلب

Reproducing the Proximal Femur Anatomy: Modular Femoral …

Rationale of modular necks.The rationale for proximal modularity with modular necks was the achievement of a better soft tissue balancing and was to reduce the occurrence of prosthetic impingement [1, 2].The best candidates for neck modularity, where the most remarkable benefits are obtained, are subjects with unconventional hip …

ادامه مطلب

Hip | DePuy Synthes

At DePuy Synthes, we're on a mission to revolutionize hip replacement and reconstruction. By creating class-leading implants, technique-inclusive offerings, and innovative technologies, we enable surgeons to develop customized solutions for every patient. Our mission is to Keep People Moving, and we want to ensure that the hundreds of ...

ادامه مطلب

Influence of Different Damage Patterns of the Stem Taper on

Background . Modularity finds frequent application in total hip replacement, allowing a preferable individual configuration and a simplified revision by retaining the femoral stem and replacing the prosthetic head. However, micromotions within the interface between the head and the stem taper can arise, resulting in the release of wear debris …

ادامه مطلب

Modularity in Total Hip Arthroplasty: Benefits, Risks

PMID: 28598491. DOI: 10.3928/01477447-20170606-01. Abstract. Modular implants are currently widely used in total hip arthroplasty because they give surgeons …

ادامه مطلب

Modular tapered conical revision stem in hip revision surgery: mid

Between January 2001 and December 2011, 101 patients underwent a hip revision arthroplasty using a fluted tapered modular stem (Revision Stem, LimaCorporate, San Daniele del Friuli, Italy). 14 patients died before the end of the 5 years evaluation; 25 patients were not reachable for different reasons, related to distance and unavailability for ...

ادامه مطلب

Modular neck stems in total hip arthroplasty: current concepts

Modular neck (MN) implants can restore the anatomy, especially in deformed hips such as sequelae of development dysplasia. Early designs for MN implants had problems with neck fractures and adverse local tissue, so their use was restricted to limited indications. Results of the latest generation of MN prostheses seem to …

ادامه مطلب

Use of a modular hip dual-mobility articulation in patients with …

Dual-mobility hip component is widely used in Europe and North America, because it effectively reduces hip dislocation in primary and revision total hip arthroplasties. However, reports were limited on the use of dual-mobility articulation in Asian populations. The aim of this retrospective study was to review the use of modular dual-mobility hip …

ادامه مطلب

Cemented unipolar or modular bipolar hemiarthroplasty for …

Introduction. Femoral neck fractures are extremely common in the elderly. Intracapsular femoral neck fractures account for over 50% of all hip fractures [].The lifetime risk of sustaining a hip fracture is high and lies within the range of 40% to 50% in women and 13% to 22% in men [].Major fracture specific risk associated with this injury is non …

ادامه مطلب

Modular neck stems in total hip arthroplasty: current concepts

Introduction. Total hip arthroplasty (THA) is a beneficial surgical procedure that relieves pain, restores hip function, and improves quality of life in most patients with end-stage hip osteoarthritis or other hip diseases. 1 However, the procedure is not entirely failure-free and new designs are continually developing. 2,3 In the late 20th century, a …

ادامه مطلب

Bilateral neck fracture in bimodular femoral stem after primary …

Several studies report complications after implantation of bi-modular femoral stems with symmetrically oval Morse taper joints in primary THA. Grupp et al. followed 5000 bi-modular Metha Short Hip stems (Aesculap AG, Tuttlingen, Germany) implanted between 2004 and 2006 and found that 1.4% of the titanium alloy necks failed after 2 years .

ادامه مطلب

Shukla Medical

SHUKLA Mod Hip is an accessory system, intended to be used with the SHUKLA Hip Mallet & Strike Plate Frame instrumentation. The system includes multiple tip configurations for universal compatibility with any modular hip stem. Strike Plate Frame and Mallet combo makes extraction simple, effective, and fast. -----PLEASE NOTE: The Strike Plate ...

ادامه مطلب

Surgical Options for Femoral Reconstruction: The Use of Modular …

The concept of modular implants has been used in total hip arthroplasty for over three decades. The concept of modular femoral heads and acetabular liners is well known to the orthopedic surgeon. McBride initially used the modular femoral stems in 1948. Bousquet and Bornard developed a proximal modular stem that featured a proximal …

ادامه مطلب

Restoration Modular Revision Hip System Surgical Protocol

Restoration Modular Revision Hip System - bizwanŠis chirurginis protokolas aprašo, kaip naudoti Restoration Modular Revision Hip System, kuris yra modulinis klubo sąnario protezas, skirtas atkurti klubo funkciją ir stabilumą. Šis sistema sudaryta iš kūgio formos kūno ir kūgio formos distalinio koto, kurie gali būti pritaikyti prie įvairių kaulų defektų ir …

ادامه مطلب

Modular neck stems in total hip arthroplasty: current …

In a retrospective series of 809 THAs using the Profemur TM stem (Wright®) with modular neck, Gofton et al35reported 2.3% dislocation on a posterior approach, …

ادامه مطلب

A Multicenter Retrieval Study of the Taper Interfaces of Modular Hip

A multicenter retrieval analysis of 231 modular hip implants was done to investigate the effects of material combination, metallurgic condition, flexural rigidity, head and neck moment arm, neck length, and implantation time on corrosion and fretting of modular taper surfaces. Scores for corrosion and fretting were assigned to medial, lateral ...

ادامه مطلب

Corrosion-wear of β-Ti alloy TMZF (Ti-12Mo-6Zr-2Fe) in

Corrosion-wear of β-Ti alloy TMZF (Ti-12Mo-6Zr-2Fe) in simulated body fluid. 2016 Sep 15;42:429-439. doi: 10.1016/j.actbio.2016.07.008. Statement of significance: TMZF is a low modulus β-Ti alloy that has been used as the femoral stem in the Stryker modular design total hip replacement. It went into service in the early 2000's but was ...

ادامه مطلب

Bilateral neck fracture in bimodular femoral stem after …

The bi-modular femoral stem is a recent innovation in primary total hip arthroplasty (THA) that enables the orthopaedic surgeon a more anatomically correct …

ادامه مطلب

Restoration Modular Revision Hip System

Restoration Moduar Revision Hip System: surgical protocol 2 Indications for Use • Noninflammatory degenerative joint disease, including osteoarthritis and avascular …

ادامه مطلب

Trunnionosis in total hip arthroplasty: a review

Trunnionosis is defined as wear of the femoral head–neck interface and has recently been acknowledged as a growing cause of total hip arthroplasty failure. Some studies have reported that it accounts for up to 3 % of all revisions. The exact cause of trunnionosis is currently unknown; however, postulated etiologies include modular …

ادامه مطلب

Arcos® Modular Femoral Revision System Brochure

The Arcos Modular Femoral Revision System meets the demands of complex hip revision surgery by offering surgeons and OR staff the ability to customize the hip implant and its corresponding instruments in a way that addresses patient and practice needs. The Arcos System's three proximal and five distal geometry options provide surgeons

ادامه مطلب

Quantification of assembly forces during creation of head-neck …

All current total hip arthroplasty (THA) systems are modular in design. Only during the operation femoral head and stem get connected by a Morse taper junction. The junction is realized by hammer blows from the surgeon. Decisive for the junction strength is the maximum force acting once in the direction of the neck axis, which is mainly …

ادامه مطلب

OsteoRemedies® Announces the First FDA Cleared Dual …

Their first introduction was the REMEDY® Spacer System. This was the first available modular system for hip, knee and shoulder two-stage infection revision arthroplasty. The REMEDY® Spacer ...

ادامه مطلب

DPW433 S-ROM Surgitech v5d

The S-ROM Modular Hip System templates incorporate 15 percent magnification. Obtain an anterior/posterior (A/P) view of the pelvis with both extremities in 15 degrees of internal rotation to position the head and neck parallel to the coronal plane. A direct lateral radiograph should also be obtained to determine desired femoral fixation.

ادامه مطلب

Modular Neck Stem Voluntary Recall Information | Stryker

Patients who have undergone total hip replacement and are unsure if they received a Rejuvenate or ABG II modular-neck stem should contact their surgeon to confirm the product implanted. Stryker's toll-free Patient Care Line can be reached by calling 1-888-317-0200 (U.S. and Canada only). The Patient Care Line is available from 8am–9pm EST ...

ادامه مطلب

Modularity in Total Hip Arthroplasty: Benefits, Risks, Mechanisms

Abstract. Modular implants are currently widely used in total hip arthroplasty because they give surgeons versatility during the operation, allow for easier revision …

ادامه مطلب

RMOD-SP-8 2013 1588 LRMCBC ST rmod-sp-1 5

Revision Total Hip Arthroplasty. 1999. pp. 100 – 111. * Capello WN, D'Antonio JA, Feinberg JR, et al., Hydroxyapatite in Total Hip Arthroplasty. Clinical Results and Critical issues, corp, 1998; Number 355: pp. 200 - 211. System Overview The Modular Cone Body/Conical Distal Stem Femoral components are part of the Restoration Modular Revision

ادامه مطلب

Modular dual mobility articulation in primary and revision …

Open access. Published: 05 April 2023. Modular dual mobility articulation in primary and revision hip arthroplasty: lights and shadows. Alessandro Moghnie, …

ادامه مطلب